7.8.3

Technical data

Memory configuration
Storage technology
Memory organization
Protocol
Data transmission rate
Multitag capability
Data retention
Read cycles
Write cycles, min.
Recommended distance to metal
Power supply
Typical read/write distance (Sg)
Degree of protection according to EN 60529
Dimensions
Material
Color
Mounting
Imprinting
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Serial number (UID)
Configuration memory
AFI/DSFID
Application memory
reading
writing
L x W (in mm)
Height
Top
Inlay
Antenna
Bottom
Ambient temperature during operation
Storage temperature
8 bytes (fixed code)
6 bytes
2 bytes
112 bytes
EEPROM
4 bytes, block by block
according to ISO 15693
approx. 3.5 ms/byte
approx. 9.5 ms/byte
Yes
10 years
Unlimited
100 000
25 mm (approx. 30% reduction of the field data)
Inductive power transmission (without battery)
See Chapter Field data (Page 35)
IP65
86 x 54
approx. 0.3 mm
PET plastic (label material)
PET plastic (carrier material)
Aluminum
Double-sided transfer adhesive on silicon
paper
White
Single-sided adhesive (self-adhesive label)
Yes, (heat transfer method)
-25 °C to +85 °C
+20 °C to +30 °C (the storage period is 2
years, determined by durability of the
adhesive)
Transponder
7.8 MDS D165
187