Battery; Replacing The Small Fan - Epson RC620 CU Manual

Robot controller
Hide thumbs Also See for RC620 CU:
Table of Contents

Advertisement

6.2 Battery

6.2.1 Replacing the Battery (Lithium Battery)
 Lithium batteries contain flammable materials such as lithium, organic
CAUTION
NOTE
Before starting battery replacement, turn on the controller for approximately one minute in
order to charge the data saving capacitor.
Make sure to finish the battery replacement within 10 minutes to prevent data loss.
Battery
(1) Backup the Controller data.
(Lithium Battery)
Removal
(2) Turn OFF the Controller.
(3) Remove cables from TP port and USB
(4) Remove 6 screws and the front panel.
RC620 Rev.8
Maintenance 6. Maintenance Parts Replacement Procedures
solvents, etc. If misused, batteries may generate heat, explode or catch
fire. Observe the following precautions for safe use of lithium batteries.
- Be sure to use the battery supplied as the maintenance parts from
EPSON. (Refer to Maintenance 9. Maintenance Parts List.)
- Do not allow the positive (+) and negative (-) electrodes to short circuit.
- Do not discard batteries into fire or heat them to high temperature.
- Do not disassemble or alter batteries.
- Do not apply a strong shock to the battery.
- Stop using the battery if you see any signs of change of color or
damage to the battery.
- When discarding batteries, insulate the terminals by wrapping them
with tape, etc.
- Discarding batteries according to the regulations.
Refer to Maintenance 4. Backup and Restore.
port on the front panel if they are
connected.
151

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc620 seriesRc620 du

Table of Contents