Setup & Operation 14. Option : Teach Pendant TP1
Specifying Point Number
There are two ways to specify the point number.
(1) Specify the point number by changing the value in the [Point] using the <↑> and <↓>
(2) Change the [Point] values directly and press the <Enter> key.
Changing Point Label
(1) Press the <F1> key and move the cursor to [Label].
(2) Enter the label name at [Label] to set the name.
(3) Press the <Enter> key.
(4) Press the <OK> key to apply the memory.
Changing Coordinate Data and Pose Flag
(1) Press the <F2> key and move the cursor to [Position: X].
(2) Move the cursor, and set the coordinate data/pose flag.
TIP
(3) Press the <OK> key to apply the memory.
Deleting Point Data
Press the <F3> key to delete the point data.
100
keys.
Chang the point number to change the indication at [Label].
Chang the point number to change the indication at [Label].
To change the orientation flag, point to the orientation flag and press the <F2> key.