Issue 6
5 - 42
4.8.5
Alarm Conditions
A brief description of each alarm condition is given below.
Alarm Indication Signal (AIS) Detection
On red when the system is receiving an Alarm
Indication Signal from an FT1 trunk.
Controlled Slip Event Detection (SLIP)
On red when the timing difference between a
synchronous receiving terminal and the received
signal exceeds the buffering ability of the terminal.
Cyclic Redundancy Check (CRC) Error Event
Detection
On red when a CRC Error occurs.
Excessive Bipolar Violation (BPV) Detection
On red when excessive BPV is detected.
Line Synchronization Alarm (LSA) Detection
On
red
synchronization.
Out-of-Frame (OOF) Condition Detection
On red when two of the four or five framing data bits
received are in error.
Remote Alarm Indication (RAI) Detection
On red when RAl is received.
4.8.6
Connectors
The DTI-U( ) ETU has one connector:
CN1
4.8.7
Connections
TELCO
Provider
when
an
FT1
Connects to the backboard
T1
CSU/DSU
Figure 5-26 DTI-U( ) ETU Connector
Installing Electronic Telephone Units
Electra Elite
trunk
loses
frame
MDF
TA
4 Wire
TB
RA
RB