Cabling Precautions

4.2.1

Cable Placement

When selecting cables and Main Distribution Frame
(MDF), future expansion or assignment changes should
be considered. Do not run cables in the following places:
4.2.2

Environmental Conditions

Temperature
Humidity
Hi-Fi Shielded Audio Cable
Hi-Fi Shielded Audio Cable
3000 feet
16,404 feet
A place exposed to wind or rain.
A place near heat radiating equipment or where the
quality of station cable covering could be affected
by gases and chemicals.
An unstable place subject to vibration.
Operating:
+32°F ~ +104°F (0°C ~ 40°C)
Long Term: +50°F ~ +90°F (10°C ~ 32.2°C)
Operating:
10% ~ 90% noncondensing
Electra Elite
Cable
Range
System Specifications