lIu (l
rror Code BIts
oad regulatIon and InterfaCe
Bit
Error
0
To high rotation
1
Load out of limit
2
DMS Offs. invalid
3
DMS Gain invalid
4
+24V out of range
5
+5V out of range
6
Brake not released.
7
Safety state mode
8
Setup not ready
9
CAN zykl. Timeout
2018111-336 Rev. B
pCB)
Reaction
Display / Info
Warning
Warning
Safety shut down
Safety shut down
Internal error
Safety shut down
Safety shut down
Safety shut down
Internal error
Safety shut down
eBike III basic / comfort
Troubleshooting
none
- advise user to cycle less than 130 rpm
- advise user to cycle between
30 and 130 rpm
- perform static calibration
- perform static calibration OFFSET
- if error persists:
reset DMS default values
- if error persists:
replace strain gauge module
- perform dynamic calibration
- if error persists:
replace strain gauge module
- check power supply
- check connections:
power supply to switch to LIU
cable DTU <-> LIU
- restart eBike (OFF / ON)
- if error persists: replace LIU
- check connections:
LIU <-> brake
LIU <-> strain gauge module
- perform static calibration
- if error persists:
reset DMS default values
- restart eBike (OFF / ON)
- if error persists:
replace LIU
- restart eBike (OFF / ON)
- if error persists:
check cable DTU <-> LIU
- check connection between
all PCB (e.g. LIU, SMU, BPU)
- replace LIU
- restart eBike (OFF / ON)
- if error persists:
check cable DTU <-> LIU
- check connection between
all PCB (e.g. LIU, SMU, BPU)
- replace LRE