GE eBike III basic Series Service Manual page 96

Electric bike with and without nibp
Table of Contents

Advertisement

e
sMu (s
rror Code BIts
Bit
Error
0
Error seat sensor
1
Seat no movement
2
Wrong cabling
3
not used
4
+24V out of range
5
not used
6
not used
7
Safety state mode
8
not used
9
CAN zykl. Timeout
- 96 -
-M
pCB)
addle
otor
Reaction
Module is switched off
Module is switched off
Module is switched off
Module is switched off
Module is switched off
eBike III basic / comfort
Display / Info
Troubleshooting
Internal error
- check cable sensor <-> SMU
- check cable motor <-> SMU
- if error persists:
check adjustment of saddle tube
replace seat motor
Internal error
- check cable sensor <-> SMU
- check cable motor <-> SMU
- if error persists:
replace seat motor
Internal error
- check cable sensor <-> SMU
- check cable motor <-> SMU
- replace cables
Warning
- check power supply
- check connections:
power supply to LIU
- replace SMU
Internal error
- restart eBike (OFF / ON)
- if error persists:
replace SMU
Internal error
- restart eBike (OFF / ON)
- if error persists:
check cable DTU <-> LIU
check connection LIU<-> SMU
- replace SMU
2018111-336 Rev. B