(3)
Parameter operation during password lock/unlock
Parameter operation
Read
Pr.296
Write
Read
Pr.297
Write
Performing parameter clear
Performing parameter all clear
Performing parameter copy

Reading/writing is unavailable when there is restriction to reading by the Pr.160 setting. (Reading is available in NET mode regardless of Pr.160
setting.)

Unavailable during the operation.

Correct password will not unlock the restriction.

Parameter clear is available only from the communication parameter.
REMARKS
 When Pr.296 = any of "4, 5, 104, 105" (password lock), the setting screen for PU JOG speed is not displayed in the parameter
unit (FR-PU07).
 During password lock, parameter copy of the parameter unit (FR-PU07) cannot be performed.
Parameters referred to
Pr.77 Parameter write selection
Pr.160 Extended function display selection
Pr.550 NET mode operation command source selection
Pr.551 PU mode operation command source selection
Misoperation prevention and parameter setting restriction
Unlocked
Pr.296  9999
Pr.296 = 9999
Pr.297 = 9999
Pr.297 = 9999




Refer to page 181
Refer to page 182
Refer to page 195
Refer to page 195
Password
Locked
registered
Pr.296  9999
Pr.296 = 100 to 106
Pr.297 = 0 to 4
Pr.297 = 5
(Read value)
(Read value)
 
 
 
 

: enabled, : restricted