Control circuit specifications
(2) Output signal
Terminal
Type
Terminal Name
Symbol
Relay output
A, B, C
(fault output)
RUN
Drive unit running
FU
Speed detection
Open collector
SE
output common
FM
For meter
(3) Communication
Terminal
Type
Terminal Name
Symbol
PU connector
USB connector
20
Description
1 changeover contact output indicates that the drive unit
protective function has activated and the output stopped.
Fault: discontinuity across B-C (continuity across AC),
Normal: continuity across B-C (discontinuity across A-C)
Switched low when the drive
unit rotation speed is equal to
or higher than the starting
rotation speed. Switched high
during stop or DC injection
brake operation.
Switched low when the drive
unit rotation speed is equal to
or higher than the preset
detected rotation speed and
high when less than the preset
detected rotation speed.
Common terminal of terminal RUN and FU.
Select one e.g. rotation speed from monitor items.
Not output during drive unit reset.
The output signal is proportional to the magnitude of the
corresponding monitoring item.
With the PU connector, communication can be made through RS-485.
Conforming standard: EIA-485 (RS-485)
Transmission format: Multidrop link
Communication speed: 4800 to 38400bps
Overall length: 500m
The USB connection with a personal computer can be established. Using FR
Configurator, setting, monitoring, and test operations of the drive unit can be
performed.
Interface: conforms to USB1.1
Transmission speed: 12Mbps
Connector: USB mini B connector (receptacle mini B type)
Rated Specifications
Contact capacity:230VAC
0.3A
(power factor =0.4)
30VDC 0.3A
 Low indicates that the
Permissible load 24VDC
open collector output
(maximum 27VDC) 0.1A
transistor is ON
(conducts).
(a voltage drop is 3.4V
High indicates that the
maximum when the signal
transistor is OFF (does
is ON)
not conduct).
Permissible load current
1mA
Output item: rotation speed
(initial setting)
1440 pulses/s at 3000r/min
Description
Reference
Page
144
144
149
155
Reference
Page
201