Speed setting signal (current) bias/gain adjustment method
Follow the following procedure to adjust the bias and gain of the speed setting voltage (current) using the operation
panel. Refer to page 173 for the details of parameters.
(a) Method to adjust any point by application of a voltage (current) across terminals 2 and 5 (4 and 5).
Operation
1.
Confirm the operation status indicator and
operation mode indicator
The drive unit should be at a stop.
The drive unit should be in the PU operation
mode. (Using
)
2.
Press
to choose the parameter setting
mode.
3.
Turn
until
appears.
4.
Press
to display
5.
Turn
until
(
Set to C4 Terminal 2 speed setting gain.
6.
Press
to display the analog voltage
(current) value (%).
7.
Apply a 5V (20mA) voltage (current).
(Turn the external potentiometer connected
across terminals 2-5 (across terminals 4-5) to
maximum (any position).)
NOTE
After performing operation in step 6, do not touch
8.
Press
to set.
Turn
to read another parameter.
Press
to return to the
Press
twice to show the next parameter (
REMARKS
 If the speed meter (display meter) connected across the terminals FM-SD does not indicate exactly 3000r/min, set the
calibration parameter C0 FM terminal calibration. (Refer to page 162)
 If the gain and bias of speed setting voltage (current) are too close, an error (
Speed setting by analog input (terminal 2, 4)
.
) appears.
indication (step 4).
Display
PRM indicator is lit.
(The parameter number read previously
appears.)
C0 to C7 setting
is enabled.
Terminal 2 input is
Terminal 4 input is
selected
selected
Analog voltage (current)
value (%) across terminals 2-
Hz
A
5 (across terminals 4-5)
Hz
A
 The value is nearly 100 (%) in the maximum position of the
potentiometer.
until completion of calibration.
Terminal 2 input is
selected
Hz
A
Flicker...Parameter setting complete!!
 The value is nearly 100 (%) in the maximum position of the
potentiometer.
).
) may be displayed at setting.
Terminal 4 input is
4
elected
175