Mitsubishi Electric FR-E700EX Instruction Manual page 159

Sensorless servo drive unit, applied
Hide thumbs Also See for FR-E700EX:
Table of Contents

Advertisement

Types of Monitor
Unit
Cumulative power 
0.01kWh 
Position command
[before electronic gear]
1
(lower 4 digits) 
Position command
10000 
[before electronic gear]
(upper 4 digits) 
Current position [before
electronic gear] (lower
1
4 digits) 
Current position [before
10000 
electronic gear] (upper
4 digits) 
Droop pulse [after
electronic gear] (lower
1
4 digits) 
Droop pulse [after
10000 
electronic gear] (upper
4 digits) 
1r/min
Ideal speed command
(0.01Hz)
1r/min
Speed command
(0.01Hz)
PID set point
0.1%
PID measured value
0.1%
PID deviation
0.1%
Drive unit I/O terminal
monitor
Motor thermal load
0.1%
factor
Drive unit thermal load
0.1%
factor

When "102 or higher" is set in Pr.144 Speed setting switchover, the speed display is enabled. For "2 to 10", the frequency display is enabled.

Speed setting to output terminal status on the PU main monitor are selected by "other monitor selection" of the parameter unit (FR-PU07).

The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from 0. When the
operation panel is used, the time is displayed up to 65.53 (65530h) in the indication of 1h = 0.001, and thereafter, it is added up from 0.

Actual operation time is not accumulated when the cumulative operation time is less than 1h until turning OFF of the power supply.

When using the parameter unit (FR-PU07), "kW" is displayed.

Since the panel display of the operation panel is 4 digits in length, the monitor value of more than "9999" is displayed "----".

Larger thermal value between the motor thermal and transistor thermal is displayed.
A value other than 0% is displayed if the surrounding air temperature (heatsink temperature) is high even when the drive unit is at a stop.

For the parameter unit (FR-PU07), the display is upper 5 digits or lower 5 digits.

The unit used for the display is 10000.
 The monitored values are retained even if an drive unit fault occurs.
Resetting will clear the retained values.
Monitor display and monitor output signal
Pr.52 Setting
Operation
PU
Pr.54 (FM)
Panel
Main
Setting
LED
Monitor
25
26
27
28
29
30
31
36
36
37
37
52
52
53
53
54
55
61
61
62
62
Terminal FM
Full Scale
Value
Adds up and displays the power amount
based on the output power monitor.
Can be cleared by Pr.170.
(Refer to page 159)
Position command [before electronic gear]
= position command [before electronic
gear] (upper 4 digits)
command [before electronic gear] (lower 4
digits)
Without a sign (always displayed as a plus
value.)
Current position [before electronic gear] =
current position [before electronic gear]
(upper 4 digits)
[before electronic gear] (lower 4 digits)
Without a sign (always displayed as a plus
value.)
Droop pulse [after electronic gear] = droop
pulse [after electronic gear] (upper 4 digits)
10000 + droop pulse [after electronic
gear] (lower 4 digits)
Without a sign (always displayed as a plus
value.)
Displays an ideal speed command for
Pr.55
creating a position command.
Displays the speed command after position
Pr.55
loop.
100%
Displays the set point, measured value and
100%
deviation during PID controlPID (Refer to
page 239 for details)
Displays the ON/OFF status of the drive
unit input terminal and output terminal on
the operation panel
(Refer to page 159 for details)
Thermal relay
Motor thermal heat cumulative value is
operation level
displayed.
(100%)
(Motor overload trip (E.THM) at 100%)
Thermal relay
Transistor thermal heat cumulative value is
operation level
displayed.
(100%)
(Drive unit overload trip (E.THT) at 100%)
Description
10000 + position
10000 + current position
157
4

Hide quick links:

Advertisement