Selection of operation mode and operation location
(3) Operation mode selection flow
In the following flowchart, select the basic parameter setting and terminal connection related to the operation mode.
START
Where is the start command source?
From outside
(STF/STR terminal)
Where is the speed command
source?
From outside
(Terminal 2, 4,
JOG, multi-speed, etc.)
From PU
(digital setting)
From communication
(PU connector communication option)
PU connector or
communication option?
PU connector (RS-485 communication)
Communication option
From the operation panel
(RUN/FWD/REV key)
Where is the speed command
source?
From outside
(terminal 2, 4, JOG, multi-speed, etc.)
From the operation panel
(digital setting)
From communication
(PU connector/communication option)
From communication
(PU connector/communication option)
PU connector or
communication option?
PU connector
(RS-485 communication)
Where is the speed
command source?
Communication option
Where is the speed
command source?
188
Connection
STF (forward rotation)/ STR
(reverse rotation)
(Refer to page 138.)
Terminal 2, 4-5 (analog), RL,
RM, RH, JOG, etc.
STF (forward rotation)/
STR (reverse rotation)
(Refer to page 138)
STF (forward rotation)/ STR
(reverse rotation)
(Refer to page 138)
Connection of communication
option
(Refer to the corresponding
communication option instruction manual)
Terminal 2, 4-5 (analog), RL,
RM, RH, JOG, etc..
Disabled
From outside
(terminal 2, 4, JOG, multi-speed, etc.)
Terminal 2, 4-5 (analog), RL,
RM, RH, JOG, etc.
From the operation panel
(digital setting)
From communication
(PU connector)
From outside
(terminal 2, 4, JOG, multi-speed, etc.)
Connection of communication
option
(Refer to the corresponding
communication option instruction
manual)
Terminal 2, 4-5 (analog), RL,
RM, RH, JOG, etc.
From the operation panel
(digital setting)
From communication
(communication option)
Connection of communication
option
(Refer to the corresponding
communication option instruction
manual)
Parameter setting
Pr.79 = "3"
(External/PU combined
operation mode1)
Communication speed setting
Pr.338 = "1"
Pr.340 = "1"
Communication speed setting
Pr.338 = "1"
Pr.340 = "1"
Pr.79 = "4"
(External/PU combined
operation 2)
Pr.79 = "1"
(fixed to PU operation)
Pr.339 = "1"
Communication start command
Pr.340 = "1"
Disabled
Communication speed setting
Pr.340 = "1"
Communication start command
Pr.339 = "1"
Communication start command
Pr.340 = "1"
Disabled
Communication speed setting
Pr.340 = "1"
Communication start command
Operation
Speed setting terminal ON
STF(STR)-ON
Operation panel, PU digital
setting STF(STR)-ON
command sending
STF(STR)-ON
command sending
STF(STR)-ON
Speed setting terminal ON
RUN/FWD/REV key ON
Digital setting
RUN/FWD/REV key ON
Speed setting terminal ON
sending
command sending
sending
Speed setting terminal ON
sending
command sending
sending