Selection of operation mode and operation location
(6) PU/External combined operation mode 1 (setting "3")
Forward
rotation
start
Reverse
rotation
start
(7) PU/External combined operation mode 2 (setting "4")
5 6
4
3
7
8
9
10
Speed
setting
potentiometer
(8) Switch-over mode (setting "6")
 While continuing operation, you can switch between the PU operation, external operation and network operation (when
RS-485 communication with the PU connector or communication option is used).
Operation Mode Switching
External operation PU operation
External operation NET operation
PU operation External operation
PU operation NET operation
NET operation External operation
NET operation PU operation
190
Drive unit
Operation
panel
STF
STR
SD
Drive unit
Operation
panel
10
2
5
Select the PU operation mode with the operation panel or parameter unit.
 Rotation direction is the same as that of External operation.
 The speed set with the potentiometer (speed command) or like is used unchanged. (Note that
the setting will disappear when power is switched OFF or the drive unit is reset.)
Send the mode change command to the Network operation mode through communication.
 Rotation direction is the same as that of External operation.
 The value set with the setting potentiometer (speed command) or like is used unchanged.
(Note that the setting will disappear when power is switched OFF or the drive unit is reset.)
Press the external operation key of the operation panel or parameter unit.
 The rotation direction is determined by the input signal of the External operation.
 The set speed is determined by the external speed command signal.
Send the mode change command to the Network operation mode through communication.
 Rotation direction and set speed are the same as those of PU operation.
Command to change to External mode is transmitted by communication.
 Rotation direction is determined by the external operation input signal.
 The set speed is determined by the external speed command signal.
Select the PU operation mode with the operation panel or parameter unit.
 The rotation direction and speed command in the Network operation mode are used
unchanged.
 Select the PU/External combined operation mode 1 when
applying speed command from the operation panel or
parameter unit (FR-PU07) and inputting the start command
with the external start switch.
 Select "3" for Pr.79. You cannot change to the other operation
mode.
 When a speed is applied from the external signal by multi-
speed setting, it has a higher priority than the speed
command from the PU. When AU is ON, the command signal
to terminal 4 is used.
 Select the PU/External combined operation mode 2 when
applying speed command from the external potentiometer,
multi-speed or JOG signal and inputting the start command
by key operation of the operation panel or parameter unit
(FR-PU07).
 Select "4" for Pr.79. You cannot change to the other operation
mode.
Switching Operation/Operating Status