Removing the Boom-Section Valves,
Supply Hoses, and Section-Valve
Mount
1. Remove the 4 flange-head bolts (5/16 x 3/4 inch) that
secure the section-valve bracket to the section-valve
mount
(Figure
18).
Note: Retain the flange-head bolts for installation in
Installing the Section Valve Manifold (page
Figure 18
1. Bracket (section-valve)
2. Lift the boom-section valves, supply hoses, and
section-valve bracket from the machine
Note: You no longer need the valves, hoses, and
bracket.
Figure 19
24).
2. Flange-head bolt (5/16 x
3/4 inch)
(Figure
19).
6
Removing the Agitation
Nozzles
No Parts Required
Removing the Agitation Nozzles from
the Sprayer Tank
1. Remove the 3 retainers that secure the agitation nozzles
to the bulkhead fittings at the left side of the sprayer
tank
(Figure
20).
Note: Retain the retainers for installation in
Installing the Agitation-Nozzle Assembly and Hoses
(page
30).
1. Bulkhead fitting
2. Agitation nozzle
2. Remove the agitation nozzles from the bulkhead
fittings
(Figure
20).
13
Figure 20
3. Retainer
13