Installing The Section-Manifold Valve; Installing The Valve Actuator - Toro Multi Pro 1750 Installation Instructions Manual

Turf sprayer
Hide thumbs Also See for Multi Pro 1750:
Table of Contents

Advertisement

Installing the Section-Manifold Valve

1. Insert the upper end-cap fitting of the manifold valve
into the bypass fitting
Note: If needed, loosen the mounting hardware for
the bypass valve as needed to provide clearance.
Figure 122
1. Flange (reducer coupling)
2. Socket (bypass fitting)
3. Bypass valve
4. Flange (adjacent
manifold—agitation valve)
5. End-cap fitting
(manifold-valve assembly)
2. Secure the end-cap fitting to the bypass fitting by
inserting a retainer into the socket of the bypass fitting
(Figure
122).
3. Assemble the outlet fitting onto the lower end-cap
fitting of the manifold valve
4. Secure the end-cap fitting to the outlet fitting by
inserting a retainer into the socket of the outlet fitting
(Figure
122)
5. Align a gasket between the flanges of the reducer
coupling and the section valve manifold
6. Assemble the reducer coupling, gasket, and section
valve manifold with a clamp, and tighten by hand
(Figure
122).
7. If installing the 2 left most section valves, align a gasket
between the flanges of the 2 adjacent section valve
manifolds
(Figure
122).
8. Assemble the 2 adjacent section valve manifolds and
gasket with a clamp, and tighten by hand
9. If you loosened the mounting hardware for the bypass
valve, tighten the nut and bolt to 1017 to 1243 N∙cm
(90 to 110 in-lb).
(Figure
122).
6. Socket (outlet fitting)
7. Retainer
8. Flange (manifold—section
valve)
9. Gasket
10. Flange clamp
(Figure
122).
(Figure
(Figure

Installing the Valve Actuator

1. Align the actuator to the manifold valve.
2. Secure the actuator and valve with the retainer that
you removed in step
(page
58).
122).
122).
58