Installing the Agitation-Manifold Valve

1. Align the flange of the agitation bypass valve, 1 gasket,
and the end-cap-fitting flange of the agitation-valve
manifold
(Figure
143).
Note: If needed, loosen the mounting hardware for
the pressure-filter head as needed to provide clearance.
Figure 143
1. Flange (pressure-filter
head)
2. Flange (agitation bypass
valve)
3. Flange (reducer coupling)
4. Flange clamp
2. Assemble the agitation bypass valve, gasket, and
agitation-valve manifold with a clamp, and tighten by
hand
(Figure
143).
3. Align a gasket between the flanges of the pressure-filter
head and the agitation-valve manifold
4. Assemble the pressure-filter head, gasket, and
agitation-valve manifold with a clamp, and tighten by
hand
(Figure
143).
5. Align a gasket between the flanges of the agitation-valve
manifold and the reducer coupling
6. Assemble the agitation-valve manifold, gasket, and
reducer coupling with a clamp, and tighten by hand
(Figure
143).
7. Align a gasket between the flanges of the agitation-valve
manifold and the adapter fitting for the agitation
throttle valve
(Figure
5. Gasket
6. Quick connect
7. Manifold (agitation valve)
8. Flange
(manifold—agitation
valve)
(Figure
143).
(Figure
143).
143).
8. Assemble the agitation-valve manifold, gasket, and
adapter fitting with a clamp, and tighten by hand
(Figure
143).
9. If you loosened the mounting hardware for the
pressure-filter head, tighten the nut and bolt to 1978 to
2542 N∙cm (175 to 225 in-lb).

Installing the Section-Manifold Valve

1. Insert the upper end-cap fitting of the manifold valve
into the bypass fitting
Note: If needed, loosen the mounting hardware for
the bypass valve as needed to provide clearance.
1. Flange (reducer coupling)
2. Socket (bypass fitting)
3. Bypass valve
4. Flange (adjacent
manifold—agitation valve)
5. End-cap fitting
(manifold-valve assembly)
2. Secure the end-cap fitting to the bypass fitting by
inserting a retainer into the socket of the bypass fitting
(Figure
144).
3. Assemble the outlet fitting onto the lower end-cap
fitting of the manifold valve
4. Secure the end-cap fitting to the outlet fitting by
inserting a retainer into the socket of the outlet fitting
(Figure
144)
5. Align a gasket between the flanges of the reducer
coupling and the section valve manifold
6. Assemble the reducer coupling, gasket, and section
valve manifold with a clamp, and tighten by hand
(Figure
144).
7. If installing the 2 left most section valves, align a gasket
between the flanges of the 2 adjacent section valve
manifolds
(Figure
61
(Figure
144).
Figure 144
6. Socket (outlet fitting)
7. Retainer
8. Flange (manifold—section
valve)
9. Gasket
10. Flange clamp
(Figure
144).
(Figure
144).
144).

Advertisement

Table of Contents