Assembling The Agitation Throttle Valve And Eductor–Shutoff Valve; Assembling The Agitation Throttle Valve - Toro Multi Pro 1750 Installation Instructions Manual

Turf sprayer
Hide thumbs Also See for Multi Pro 1750:
Table of Contents

Advertisement

Connecting the Electrical Connectors
for the Rate Valve, Agitation Valve, and
Master-Spray Valve
1. Connect the 3-pin valve harness labeled
into the 3-socket connector for the master-spray
VALVE
valve
(Figure
57).
Figure 57
1. 3-socket valve harness
(master-spray valve)
2. 3-socket valve harness
(agitation valve)
3. 4-socket valve harness
(rate switch)
2. Connect the 3-pin valve harness labeled
into the 3-socket connector for the agitation
VALVE
valve
(Figure
57).
3. Connect the 4-pin valve harness labeled
into the 4-socket connector for the rate valve
57).
-
MASTER
SPRAY
4. 3-pin adapter harness
(master-spray valve)
5. 3-pin adapter harness
(agitation valve)
6. 4-pin adapter harness
(rate switch)
AGITATION
RATE VALVE
(Figure
12
Assembling the Agitation
Throttle Valve and
Eductor–Shutoff Valve for
Machines with the Optional
Eductor Kit
Parts needed for this procedure:
1
Handle
1
Screw (6-32 x 5/8 inch)
1
Agitation throttle valve
1
Bracket (nylon)
1
Agitation-valve bracket
4
Bolt (6 x 12 mm)
1
Eductor-shutoff valve
1
Eductor-shutoff bracket
4
Flange locknut (1/4 inch)
2
Flange-head bolt (5/16 x 3/4 inch)

Assembling the Agitation Throttle Valve

1. Assemble the handle to the agitation throttle valve
(Figure
58) with the screw (6-32 x 5/8 inch).
28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

136-0372