Siemens SINAMICS S120 Combi Equipment Manual page 104

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

S120 Combi Power Modules
3.7 Technical data
4 axes Power Module
DC link capacitance
Circuit breaker (UL)
Type designation
Rated current:
Resulting rated short-circuit current
SCCR at 480 V
AC
Fuses (UL)
Type AJT Class J
4)
Rated current
Resulting rated
short-circuit SCCR
at 480 V
AC
at 600 V
AC
Cooling method
Cooling air requirement
Weight
1) The specified power ratings apply for the line supply voltage range from 380 V to 480 V
2) The external fan unit 6SL3161-0EP00-0AA0 has been taken into account for the specified losses - also refer to the
power loss calculation for partial load operation in Chapter "Control cabinet installation".
3) For an overview, see the power loss tables in Chapter "Control cabinet installation"
4) Source of supply: Ferraz Shawmut, http://de.ferrazshawmut.com
104
6SL3111-
4VE21-6FA0
μF
1645
3VL2105-2KN30
A
50
kA
65
AJT 35
A
35
kA
65
kA
200
External air cooling
m
/h
160
3
kg
18.9
4VE21-6EA0
4VE22-0HA0
2115
2520
3VL2105-2KN30
3VL2106-2KN30
50
60
65
65
AJT 35
AJT 60
35
60
65
65
200
200
160
160
18.95
19.05
SINAMICS S120 Combi
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0

Advertisement

Table of Contents
loading

Table of Contents