Notes on electromagnetic compatibility (EMC)

Requirements to implement EMC are listed in EN 61000-6-2, EN 61000-6-4, EN 61800-3,
EN 60204-1 and in the EMC installation guideline - Order No. 6FC5297-0AD30-0*P2
(*A: German, *B: English). Conformance with the EMC Directive of the EC can be secured
by following the measures described in the EMC installation guideline.
When mounting components in cabinets, in order to fulfill the EMC Directive, the following
conditions must be additionally observed:
● Connected to TN and TT line supplies with grounded neutral point and grounded phase
● Observance of information about cable shielding and equipotential bonding.
● Only the recommended Siemens power and signal cables are used
● Only cables from Siemens may be used for DRIVE-CLiQ connections.
CAUTION
If couplings or cabinet glands are needed for the DRIVE-CLiQ connections, only the
DRIVE-CLiQ coupling and DRIVE-CLiQ cabinet gland, described in the Chapter
Accessories, may be used.
If the shielding procedures described and the specified cable lengths are not observed, the
machine may not operate properly.