Encoder system connection
10.3 Sensor Module External SME25
10.3.4
Installation
Figure 10-12 SME20/SME25 installation
Procedure
1. Place the drilling pattern on the bright contact surface
2. Holes Ø 5.3 or threads M5
3. Tighten with a min. torque of 6 Nm.
230
SINAMICS S120 Combi
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0