Replacing The Fan On The Motor Modules Booksize Compact - Siemens SINAMICS S120 Combi Equipment Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Service and maintenance
13.3 Replacing the fan
13.3.2

Replacing the fan on the Motor Modules Booksize Compact

NOTICE
When replacing the fan, you must observe the ESD regulations.
Only qualified personnel are permitted to install spare parts!
Risk of electric shock
Switch off the power supply (400 V AC) before replacing the fan. A hazardous voltage is
still present for up to 5 minutes after the power supply has been switched off.
Before removing the component, check that the system is in a no-voltage condition!
Table 13- 2
Removing the fan
Module width: 50 mm
Removing the Motor Module from the drive line-up
Remove the fan cover at the lower side of the Motor Module by releasing the snap hook
280
DANGER
Module width: 75 mm
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0
SINAMICS S120 Combi

Advertisement

Table of Contents
loading

Table of Contents