X523 Digital Outputs - Siemens SINAMICS S120 Combi Equipment Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Additional system components
9.1 Terminal Module TM54F
NOTICE
For the digital inputs DIx+ to function, the particular reference potential must be connected
to input DIx.
This is achieved by:
1) Routing the ground reference of the digital inputs as well, or
2) A jumper between DIx and terminal M1.
9.1.3.8

X523 digital outputs

Table 9- 7
Screw terminal X523
Terminal
1
2
3
An F-DO comprises two digital outputs and a digital input to feed back the signal
F-DO 0 = terminals 1, 2 and 3
Max. connectable cross-section: 1.5 mm²
Type: Screw terminal 1 (see Chapter "Control cabinet installation and EMC / connection system")
1) DI: Digital input; DO: Digital output
2) Pure hardware delay
182
Designation
Technical specifications
1)
DI 20
Voltage: - 3 V to +30 V
Typical current consumption: 3.2 mA at 24 V DC
Electrical isolation: Reference potential is
Terminal M1
The digital input is electrically isolated.
Input delay:
- for "0" to "1": 30 μs (100 Hz)
- for "1" to "0": 60 μs (100 Hz)
Level (incl. ripple)
High level: 15 V to 30 V
Low level: -3 V to 5 V
DO 0+
0.5 A
Reference potential is terminal M1
0.5 A
DO 0-
Reference potential is L1+, L2+ or L3+
Output delay:
- for "0" to "1": 300 μs
- for "1" to "0": 350 µs
Total current consumption of all DOs: 2 A
Max. leakage current: < 0.5 mA
Switching frequency:
For resistive load: Max. 100 Hz
For inductive load: Max. 0.5 Hz
For lamp load: Max. 10 Hz
Maximum lamp load: 5 W
2)
2)
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0
SINAMICS S120 Combi

Advertisement

Table of Contents
loading

Table of Contents