Encoder system connection
10.1 Sensor Module Cabinet-Mounted SMC20
10.1.6

Technical data

Table 10- 5
Technical data
6SL3055-0AA00-5BAx
Electronics power supply
Voltage
Current (without encoder system)
Current (with encoder system)
Power loss
Encoder system power supply
Voltage
Current
Encoder frequency that can be evaluated
(f
)
encoder
SSI baud rate
2)
Max. encoder cable length
PE/ground connection
Weight
Degree of protection
1) A controller compares the encoder system supply voltage - sensed via the Remote Sense cables - with the reference
supply voltage of the encoder system, and adjusts the supply voltage for the encoder system at the output of the drive
module until the required supply voltage is obtained directly at the encoder system (only for 5 V encoder system power
supply).
2) Only possible for SSI encoders with 5 V supply
218
Unit
Value
V
24 DC (20.4 – 28.8)
DC
A
≤ 0.20
DC
A
≤ 0.35
DC
W
≤ 10
V
5 V DC (with Remote Sense)
encoder
A
0.35
encoder
kHz
≤ 500
kHz
100 (6SL3055-0AA00-5BA2)
100 - 250 (6SL3055-0AA00-5BA3)
m
100
On housing with M4/1.8 Nm screw
kg
0.45
IP20 or IPXXB
1)
SINAMICS S120 Combi