9.1.3.11

X531 digital inputs and dynamically adjustable power supply

Table 9- 10
Screw terminal X531
Terminal
1
2
3
4
5
6
7
8
An F-DI comprises a digital input and a 2nd digital input where, in addition, the cathode of the optocoupler is fed-out.
F-DI 5 = terminals 2, 3 and 6
F-DI 6 = terminals 4, 5 and 7
Max. connectable cross-section: 1.5 mm²
Type: Screw terminal 1 (see Chapter "Control cabinet installation and EMC / connection system")
1) DI: Digital input; M1: Ground reference
2) Pure hardware delay
NOTICE
For the digital inputs DIx+ to function, the particular reference potential must be connected
to input DIx.
This is achieved by:
1) Routing the ground reference of the digital inputs as well, or
2) A jumper between DIx and terminal M1.
SINAMICS S120 Combi
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0
Designation
Technical specifications
1)
L 2+
Voltage: +24 V DC
Max. total load current: 500 mA
DI 10
Voltage: - 3 V to +30 V
Typical current consumption: 3.2 mA at 24 V DC
DI 11+
Electrical isolation: Reference potential, refer to
DI 12
terminals 6, 7, 8
DI 13+
All digital inputs are electrically isolated.
Input delay:
- for "0" to "1": 30 μs (100 Hz)
- for "1" to "0": 60 μs (100 Hz)
Level (incl. ripple)
High level: 15 V to 30 V
Low level: -3 V to 5 V
DI 11-
Reference potential to DI 11+
DI 13-
Reference potential to DI 13+
M1
Reference potential to DI 10, DI 12, L2+