Drive-Cliq Signal Cables - Siemens SINAMICS S120 Combi Equipment Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

12.7.3

DRIVE-CLiQ signal cables

Note
Only MOTION-CONNECT 500 and MOTION-CONNECT 800 DRIVE-CLiQ cables are
permitted for the connection. The maximum cable length for MOTION-CONNECT 500 cables
is 100 m, for MOTION-CONNECT 800 cables, 50 m.
If DRIVE-CLiQ couplings are used, the permissible cable length can be calculated as
follows:
ΣMC500 + 2 x ΣMC800 + n
ΣMC500: Total length of all MC500 cable sections
ΣMC800: Total length of all MC800 cable sections
n
: Number of DRIVE-CLiQ connectors (max. 0...3)
C
Table 12- 8
Comparison between DRIVE-CLiQ MOTION-CONNECT 500 and MOTION-CONNECT 800 cables
DRIVE-CLiQ signal cable
Approvals
VDE
cUL or UL/CSA
UL-CSA File No.
1)
RoHS conformance
Rated voltage V
/V
0
in accordance with EN 50395
Test voltage, rms
Operating temperature at the surface
Permanently installed
Moveable
Tensile load, max.
Permanently installed
Moveable
Smallest bending radius
Permanently installed
Moveable
Torsional stress
Bending operations
Max. traversing speed
Max. acceleration
insulation material
Oil resistance
Protective jacket
Flame retardant
1) The file number is printed on the cable jacket.
SINAMICS S120 Combi
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0
x 5 m ≤ 100 m
C
MOTION-CONNECT 500
Yes
UL STYLE 2502/CSA-N.210.2-M90
Yes
Yes
30 V
500 V
-20 to +80°C
0 to 60°C
80 N/mm
2
30 N/mm
2
35 mm
125 mm
30°/m absolute
100000
30 m/min
2 m/s
2
CFC/silicone-free
EN 60811-2-1
(mineral oil only)
PVC
EN 60332-1-1 to 1-3
Cabinet design and EMC
12.7 Cable shielding and routing
MOTION-CONNECT 800
Yes
UL STYLE 20236/CSA-N.210.2-M90
Yes
Yes
30 V
500 V
-20 to +80°C
-20 to +60°C
50 N/mm
2
20 N/mm
2
60 mm
100 mm
30°/m absolute
10 million
180 m/min
5 m/s
(5 m); 10 m/s
(2.5 m)
2
2
CFC/halogen-free/silicon-free
EN 60811-2-1
PUR, HD22.10 S2
(VDE 0282, Part 10)
EN 60332-1-1 to 1-3
257