Electrically connecting Motor Modules and DC link components
8.4 Connecting an additional component
3. Install the lower and upper DC link busbars
Install the lower DC link busbar
• Release the screws
• Turn the DC link bridge
• Observe the sequence when tightening
Screwdriver
Tightening torque
4. Install the red 24 V connector (completion kit of the component to be connected)
5. Close the protective covers of both components
174
the screws
Torx T20
1.8 Nm
Figure 8-4
Motor Modules with installed 24 V connector
CAUTION
Before commissioning the drive line-up, it must be ensured, that:
• The DC link side cover is inserted at the outer component (touch protection).
• The protective covers of all of the components are closed.
Install the upper DC link busbar
• Release the screws
• Remove the plastic cap on the DC link
bridge
• Turn the DC link bridge
• Observe the sequence when tightening
the screws
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0