Time In A Ucd Queue; Waiting Message Before Signaling A Ucd Call - Siemens HiPath 1100 Series Programming Manual

Table of Contents

Advertisement

Programming an Extension
Step by Step
0 0
*
52

Time in a UCD Queue

This setting specifies the maximum length of time a call
is allowed to remain in a UCD Queue.
Once the time expires the call is disconnected or
forwarded to a UCD overflow call extension. The default
setting for a call to remain in a Queue is 1 minute.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
0 3 1
Enter the UCD Subscriber Group number (790 to 799).
...
Enter the time allowed for a call to remain in a Queue
9 9
(00 to 99 in 5-second increments) where 00 = 0
seconds... 06 = 30 seconds ... 12 = 1 minute (default),
etc.
Enter the next UCD Subscriber Group number
or
Press this key.
#
Initial state for Programming Mode.

Waiting Message before Signaling a UCD Call

This feature allows you to connect a call waiting
message for incoming calls before they ring at a UCD
extension.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
0 3 2
Enter the UCD Subscriber Group number (790 to 799).
or
Activate/Deactivate call waiting message:
#
*
= To activate
= To deactivate (default)
#
Enter the next UCD Subscriber Group number
or
Press this key.
#
Initial state for Programming Mode.