Fax/DID Module
Music Module
CD 16 Module
TFE Door Opener interface
Total System Capacity
External
line/extension/system
telephones
Total external analog lines without
a TME1 or a S
module
0
1.When the maximum capability for external lines is exceeded due to the installation of EB, S
ules, the system disables a number of external analog lines, adjusting the capability as needed for each sys-
tem. The extensions slots, however, will continue to operate as usual.
For example, HiPath 1130
- Slot 0, MB 210,
- Slot 1, EB 210,
- Slot 3, TME1- 15 channels
In this case the external lines for EB 210 will not enabled, but the extension will.
2.
0 and TME1 modules cannot be used simultaneously.
S
On the HiPath 1150 and HiPath 1190 ADSL and TME1 modules can be used simultaneously.
3.When using an external digital line, the maximum number of analog lines is calculated by subtracting the num-
ber of configured lines in each module from the total capacity of the lines.
Example 1: HiPath 1150
- Slot 0, MB 210
- Slot 3, S
- 5 ports = 10 external lines
0
Overall, there are 17 external lines at a maximum available on the system. This means there is room for 5 addi-
tional external analog lines.
10 S
external digital lines + 2 MB external analog line = 12 external lines.
0
An EB 400 could be used in Slot 1 or Slot 2. There are no 5-port modules.
If an EB 800 was installed on the switch, the entire module would be inoperable since it would exceed the sys-
tem's maximum capacity for external lines.
Example 2: HiPath 1150
- Slot 0, MB 210
- Slot 3, TME1 = 15 external lines
Overall, there are 17 external lines at a maximum available on the system. This means there is no room for an
additional EB module with an external analog line.
15 CAS external digital lines + 2 MB external analog lines = 17 external lines
If an EB 200 was installed in Slot 1 or Slot 2 the module would not be operable, since it would exceed the sys-
tem's maximum capacity for external lines.
Example 3: HiPath 1150
- Slot 0, MB 210
- Slot 3, TME1 = 10 external lines (disable the channels in the TME1 Module and configure unused external lines
as Vacant by turning the switch off then on again).
Overall, there are 12 external lines on the system. This means there are 5 additional external lines available
before reaching the maximum capacity of 17 external lines.
10 CAS external digital lines + 2 MB external analog lines = 12 external lines.
An EB 400 could be used in Slot 1 or Slot 2. There are no 5-port modules.
If an EB 800 was installed on the switch, the entire module would be inoperable since it would exceed the sys-
tem's maximum capacity for external lines.
HiPath 1120 HiPath 1130 HiPath 1150 HiPath 1190
1
6/16/4
6
3
1
on board
0
4
10/50/8 or
17/20/8
16/40/8 or
16/20/8
17/46/8
14
16
Features and Options
1
32/140/24 or
45/140/24
32
or TME1 mod-
0
7