CH1 Range setting monitor
Common
The output range value set to the output range setting or 'CH1 Range setting' (Un\G598) can be checked.
Monitored value
0H
1H
2H
3H
4H
EH
FH
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH Range setting monitor
The output range cannot be changed for a channel where D/A conversion is disabled, and thus a value stored
in this area is not updated. For details, refer to the following.
Page 20 Range Switching Function
CH1 HOLD/CLEAR function setting monitor
Common
The setting status of the analog output HOLD/CLEAR function can be checked.
Monitored value
0
1
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH HOLD/CLEAR function setting monitor
CH1 Wave output conversion cycle monitor
Wave
This area stores the wave output conversion cycle in 32-bit signed binary for each channel.
The unit of the stored value is s.
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH Wave output conversion cycle monitor
■Update of the stored value
When 'Operating condition setting request' (Y9) is turned on and off, the stored value is updated.
Description
4 to 20mA
0 to 20mA
1 to 5V
0 to 5V
-10 to 10V
User range setting (voltage)
User range setting (current)
CH1
CH2
430
630
Description
CLEAR
HOLD
CH1
CH2
431
631
CH1
CH2
432, 433
632, 633
CH3
CH4
830
1030
CH3
CH4
831
1031
CH3
CH4
832, 833
1032, 1033
APPX
Appendix 3 Buffer Memory Areas
A
163