When an error occurs
When a value out of the setting range is tried to be output, a digital value setting range error (error code: 191H) occurs.
When a digital value setting range error (error code: 191H) occurs during the wave output, the analog output value becomes
as follows.
• If the value to be output is greater than the maximum value of the output range, the maximum value of the output range is
output in analog.
• If the value to be output is smaller than the minimum value of the output range, the minimum value of the output range is
output in analog.
When a digital value setting range error (error code: 191H) has occurred, correct the digital value of the wave data so that
the value is within the output range. Then, turn on and off 'Error clear request' (YF).
• When the output range is set to "0 to 5V":
Wave data
Digital value
32000
0
(1) A digital value setting range error (error code: 191H) occurs.
(2) If the value to be output is smaller than the minimum value of the output range, the minimum value of the output range is output in analog.
(3) If the value to be output is greater than the maximum value of the output range, the maximum value of the output range is output in analog.
To check the buffer memory address where the wave data with the value out of the range is registered, use 'CH1 Wave output
digital value outside the range address monitor' (Un\G440, Un\G441).
1 FUNCTIONS
74
1.14 Wave Output Function
CPU module status
'CH1 D/A conversion
enable/disable
setting' (Un\G500)
'CH1 Output enable/disable
flag' (Y1)
'CH1 Wave output start/stop
request' (Un\G462)
'CH1 Wave output status
monitor' (Un\G401)
Analog output
Maximum value of
the set output range
(5.12V)
Output according to the setting of
'CH1 Output setting during wave
output stop' (Un\G524)
Offset value
Minimum value of
the set output range
(-0.12V)
D/A conversion enable (0)
OFF
Wave output stop
request (0)
During wave
During wave
output (1)
output stop (0)
(1)
RUN
ON
Wave output start request (1)
During wave
output stop (0)
(3)
(2)