ADA2 Adapter (Figure 4-31 - Figure 4-38)

Using the ADA2 Adapter provides a recording jack connection which provides a connection from an Aspire
IPhone to an external tape recorder or speaker. The adapter output is a 1/8" audio jack which you can con-
nect directly to an AUX level input on a recorder or page amplifier. The recorder input can also be wired
directly to the terminals on the inside of the adapter. As the IPhone only has one connector available for
additional adapters, if this adapter is connected, no other adapter can be installed on the phone.
When installing or removing the adapters, the keyset should first be unplugged from the system. Telephones
with any adapters installed cannot be wall-mounted. The bracket will not accommodate the adapter(s).
Be sure the connected audio device provides a standard AUX level input.
The use of monitoring, recording, or listening devices to eavesdrop, monitor, retrieve, or
record telephone conversation or other sound activities, whether or not contemporaneous
with transmission, may be illegal in certain circumstances under federal or state laws. Legal
advice should be sought prior to implementing any practice that monitors or records any
telephone conversation. Some federal and state laws require some form of notification to all
parties to a telephone conversation, such as using a beep tone or other notification methods
or requiring the consent of all parties to the telephone conversation, prior to monitoring or
recording the telephone conversation. Some of these laws incorporate strict penalties.
The handset only records when a call is placed or answered.

Installing the ADA2 Adapter:

1. Unplug the LAN cable and AC adapter cable from the keyset if previously installed.
2. The adapter should be installed on the right-hand side of the phone (beneath the handset). Using a
flat-head screwdriver, remove the plastic punch-out piece covering the connector.
3. Set the dip switches on the ADA2 adapter to the required position. The SW1 switch should be set to
"2" and the SW2 switch should be set to "1".
(1=620 Ohms, 2=30 Ohms). The SW2 switch should remain in the "1" position.
Aspire S Hardware Manual
Section 4: Telephones and Optional Equipment
The SW1 indicates the type of adapter (2=ADA2) and the SW2 switch sets the impedance
SW1, SW2
ADA2 Module
Figure 4-31: RECORDING DIP
SWITCH SETTINGS
Section 4: Telephones and Optional Equipment ◆ 4-35
CAUTION
SW1, SW2
ON
1
2 3 4 5 6 7 8
Figure 4-32: PLAYBACK DIP
ADA2 Module
ON
1
2 3 4 5 6 7 8
SWITCH SETTINGS