Ports for APR Adapter

The APR Adapter's extension number is determined when the adapter is connected to the keyset. After
assigning the APR Adapter a circuit type of '12' in Program 10-03-06, the system automatically selects the
next available port within the APR's range (11-26). The system assigns the ports numbers from highest to
lowest (26, 25, 24, etc.). Program 10-03-07 indicates which port is assigned for the APR Adapter. You can
reassign the extension number for the port using Program 11-02-01. When installing the APR adapter, there
must be an extension port available for the adapter or it will function like an APA adapter (only one physical
port assigned to the phone so only one phone can be used at a time).
Use the table below to determine the extension number associated with the port number.

Programming for System and Alarm Reports

90-12-01 : System Alarm Output - Output Port Type
Indicate the type of connection used for the System Alarms. The baud rate for the COM port should be
set in Program 10-21-02 (0=No setting, 1=COM port (CPU), 4=CTA/CTU).
90-12-02 : System Alarm Output - Destination Extension Number
If the output port type (item 1) is set to CTA, enter the extension number with the CTA connection.
90-12-06 : System Alarm Output - Output Mode
Indicate if the output for the alarms should be manual (0) or automatic (1).
90-13-01 : System Information Output - Output Port Type
Indicate the type of connection used for the SMDR (0=No setting, 1=COM port (CPU), 4= CTA/CTU).
90-13-02 : System Information Output - Destination Extension Number
If the output port type (item 1) is set to CTA, enter the extension number with the CTA connection.
90-13-03 : System Information Output - Output Command
Dialing 1 from this program sends the system report to the connected device.
Use the following programs for outputting or clearing the alarm reports:
90-12-03 : System Alarm Output - Output All Alarm Reports
90-12-04 : System Alarm Output - Printout New Alarm Reports
90-12-06 : System Alarm Output - Clear All Alarm Reports
Refer to Data Communications in the Software Manual for additional details.
Aspire S Hardware Manual
APR Extension Port Number
11
12
:
25
26
Section 5: Data and SMDR
Extension Number
311
312
:
325
326