The ground lug descriptions are as follows:
PBXG (CO/PBX Ground)
The grounding wire from the COIU or DIOPU PCBs are connected to the PBXG terminal plate. A
grounding wire should then be connected from the PBXG terminal plate to a known earth ground when
these PCBs are installed in the system.
ETH (Earth Ground)
This ground lug is used for lightning protection. It should always be connected to the earth.
FG (Frame Ground)
This ground lug is connected from the power supply cable to the metal frame of the main equipment.
Aspire S Hardware Manual
This grounding wire should be separate from the ETH grounding wire.
This grounding wire should be separate from the PBXG grounding wire.
Section 1: Installing the Cabinet
Section 1: Installing the Cabinet ◆ 1-19