NEC UPD98413 User Manual page 242

Table of Contents

Advertisement

(75) Transmit ATM/POS layer event detection registers (DAPET)
The DAPET registers indicate whether the occurrence of each event was detected.
Register Name
Port0:
DAPET_RWC
01B0 H
DAPET_RC
01B4 H
31
30
29
28
15
14
13
12
Bit
Field
Reserved
Reserved
D31-D4
D3
FUPCT
1: Detects occurrence of an overflow in transmit FIFO underflow packet counter.
0: Does not detect.
D2
APCT
1: Detects occurrence of an overflow in transmit abort packet counter.
0: Does not detect.
D1
VPCT
1: Detects occurrence of an overflow in transmit valid cell/packet counter.
0: Does not detect.
D0
ABOE
1: Detects occurrence of transmit abort packet due to a transmit FIFO underflow.
0: Does not detect.
242
CHAPTER 5 REGISTERS
Address
Port1:
Port2:
Port3:
05B0 H
09B0 H
0DB0 H
05B4 H
09B4 H
0DB4 H
27
26
25
24
Reserved
11
10
9
8
Reserved
PRELIMINARY
Access
Default
R/WC
00000000 H
RC
00000000 H
23
22
21
20
7
6
5
4
FUPCT
Function
NEC confidential and Proprietary
Function
Read-only / Write clear
Read clear
19
18
17
16
3
2
1
0
APCT
VPCT
ABOE
Default
All 0
0
0
0
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neascot-p65

Table of Contents