2) Watch monitor
With the watch monitor, the variables to be constantly displayed can be selected.
When the [Watch] button on "Program monitor window" is tapped on, the watch monitor window and a
window for selecting the variables to be displayed will appear.
<a>
[Select variable] The watched variable can be selected from the variable list used by the program.
<b>
<g>
<b>
<c>
When [Select value] button (<b>) is tapped, the following screen is displayed.
[Add] button (<e>) is tapped after the variable watched on this screen is selected, and
the variable monitored to "Displayed variables" is selected. If all the variables to wish
are selected, tap the [OK] button. (<f>)
The variable, which is not displayed here can be specified by the [Add variable] button.
(<a>)
When the [Update] button (<f>) is tapped, the variable of the program loaded into the
task slot is acquired again.
<d>
<e>
<f>
98