18.4. Language of T/B

You can change the language of the T/B. Select the language (<a>) and tap [Write] button.

18.5. IP address of T/B

You can set the IP address of the T/B. Tap [Setting] button (<a>). After you tap [Setting] button (<a>), you can
see the screen as follows. You can set IP address, Subnet Mask, and Default gateway.
When changing the IP address of the CR7xx-Q controller, please set the IP address as shown in the table
below. You can confirm the controller's IP address by Ethernet parameter screen (refer to chapter 0).
Set an IP address different only for the IP address and
host address of the robot controller.
When connecting to other series, type controller, please
return to factory shipment state (192.168.100.50).
CR7xx-Q
<a>
CR800-D/Q/R, CR7xx-D
Return to the factory shipment state.