11.3.9.

Edit of position data for SQ Direct Function in the USB memory

1) Select the [USB] in the Program list screen, select the file of position data for SQ Direct Function edited (<a>)
in the list, and tap the [Open] button (<b>).
2) The SQ Direct position edit screen is displayed. The procedure of editing position data for SQ Direct Function
is the same as case of editing in the controller. Please refer to "11.3.1 Registering the current position data
for SQ Direct Function", "11.3.2 Edit of position data for SQ Direct Function", "11.3.3 Addition of
position data for SQ Direct Function" and "11.3.4 Initialization of position data for SQ Direct Function"
for detail.
3) Tap the [Save] button (<c>) if edit is completed. And the file in the USB memory is overwritten.
<a>
CAUTION
Do not write-protect the USB memory when you do the operation as write
to it.
Even if it seems to have been able to write it without the error occurring by the operation copy and
delete etc., when write-protection of USB memory is released, all operation is canceled. And an
empty (size 0) file might be generated.
CAUTION
Please tap the [Save] button after changing (edit, add, delete, and teach)
the position data for Sequencer Direct function in the USB memory.
In the case of the position data for Sequencer Direct function in the controller, the value in the
controller is changed when the value is changed by each operation; edit, add, delete and teach.
But otherwise in the case in the USB memory, please execute the save operation by the [Save]
button after value changed by edit, add, delete and teach. When the screen is switched without
saving, the changed value is not written in the file.