Recommended Test Equipment; Ac Power Grounding - HP 5501A Operating And Service Manual

Laser transducer system
Hide thumbs Also See for 5501A:
Table of Contents

Advertisement

d.
The installation of the electronic interface components. These procedures are divided
into major system configurations. Select the procedure that matches your system.
e.
The system checkout procedure. These procedures are divided into major system con-
figurations. Select the procedure that matches your system.
f.
Preventive Maintenance. The system electronics require no preventive maintenance.
However, the system optics do require periodic cleaning. The frequency of the cleaning
is dependent on the cleanliness of the ambient environment.
The procedures are organized in this manner to make installation and checkout a s simple a s
possible.
In
addition, they can be used a s a basis for detailed troubleshooting either during
initial installation or at a later time when a system problem cannot be easily located. Table
5-7
i s a list of recommended test equipment needed to install, check out, and troubleshoot the
Laser Transducer System. Other equipment can be used if it meets the minimum specifications
listed.
Table
5-7.
Recommended
Test
Equipment
1
Description
Required Characteristics
I
Recommended Model
I
I
DC
Voltmeter
1
k15V
i0.025V
and
+5V
i0.01V
1
HP
3435A
1
Logic
Probe
Ability
t o
Indicate
TTL
and
/
HP
10525T/10525E
ECL
Logic
Levels
I
Oscilloscope
I
Ability
t o
Display
Signals
I
HP
180A/1801A/1820A
between
DC
and
20
MHz
5.2
SYSTEM
GROUND
CONSIDERATIONS
IF
proper
system
grounding
techniques
are
not
observed,
two
adverse
situations
can
occur:
a.
A
system
can
be
interconnected
so
that
an
electrical
shock
hazard
exists.
External
parts
of
various
system
components
can
be
at
different
electrical
potentials
due
to
in-
complete
system
grounding.
(See
Figure
5-7).
ISOLATED
FROM
GROUND
AT
SUPPLY
\
(
: : : :
SYSTEM
COMMON
MOTOR
5501A
I
\
--
I
-
-A
MACHINE
SThUCTURE
+ 1 5 V
SUPPLY
SAME
EARTH
-
GROUND
CONNECTION
L /
-
NOTES:
1
Laser head
IS
grounded by belng phys~cally mounted on the work
table Power supply
IS
grounded for safety, but ~ t s outputs are
Isolated from ground
2
Motor currents cannot travel through power supply system
common because thls lhne
IS
Isolated from earth ground at the
power supply. It
IS
at ground
potential,
however, because the
5501A
IS
grounded
3.
When
thls
grounding
system
IS
used,
do
not
connect
"system
common"
to
earth
ground
at
the
power
supply.
Be
sure,
however,
that
the
laser
head
IS
grounded
to
the
machlne
work
surface.
Figure
5-7.
AC
Power
Grounding

Advertisement

Table of Contents
loading

Table of Contents