6.6

Input signal selection

6.6.1
f105 : Priority selection (Both F and R are ON)
 Function
[Parameter setting]
f105
(1) [f105 = 0 (Reverse)]: If an F command and an R command are entered simultaneously,
6
Output frequency [Hz]
Priority selection (Both F and R are ON)
This parameter allows you to select the direction in which the motor runs when a forward run (F)
command and a reverse run (R) command are entered simultaneously.
1) Reverse
2) Deceleration stop
Title
Function
Priority selection
(Both F and R are ON)
the motor will run in the reverse direction.
Setting frequency
0
Setting frequency
Forward run command
Reverse run command
Adjustment range
0: Reverse
1: Deceleration stop
F-28
E6581611
Default setting
1
Forward run
Time [s]
Reverse run
ON
OFF
ON
OFF

Advertisement