6.35 Tracing functions

f740 : Trace selection
f741 : Trace cycle
⇒For details, refer to "Trace Function Instruction Manual : E6581922".

6.36 Integrating wattmeter

f748 : Integrating wattmeter retention selection
f749 : Integrating wattmeter display unit selection
6
• Function
At the main power off, display unit of integral output power values and whether or not retain integral output
power values are selectable.
The integrating wattmeter display can be cleared by the signal to the input terminal.
Input terminal function 74, 75 (Integrating wattmeter display clear)
Title
f748
f749

6.37 Parameter registration to easy setting mode

f750 : EASY key function selection
f751 to f782 : Easy setting mode parameter 1 to 32
Up to 32 arbitrary parameters can be registered to easy setting mode.
⇒ Refer to section 4.5 for details.
Function
Integrating wattmeter retention selection
Integrating wattmeter display unit selection
f742 : Trace data 1
f743 : Trace data 2
f744 : Trace data 3
f745 : Trace data 4
Adjustment range
0: Disabled
1: Enabled
0:1=1kWh
1:1=10kWh
2:1=100kWh
3:1=1000kWh
4:1=10000kWh
F-134
E6581611
Default setting
0
Depends on
the capacity
(Refer to
section 11.4)