Toshiba Q9 Plus Bypass ASD Installation & Operation Manual page 329

Hide thumbs Also See for Q9 Plus Bypass ASD:
Table of Contents

Advertisement

 List of logic input terminal function settings
Parameter
programmed value
Positive
Negative
logic
logic


No function


Forward run command
Reverse run command




Standby


Reset command
Preset-speed command 1
 
 
Preset-speed command 2
 
 
 
 
Preset-speed command 3
 
 
Preset-speed command 4
 
 
Jog run mode
Emergency stop by external signal
 
 
 
 
DC braking command
2nd acceleration/deceleration
 
 
3rd acceleration/deceleration
 
 
 
 
2nd V/F control mode switching
2nd stall prevention level
 
 
PID control prohibition
 
 
External thermal error input
 
 
Forced local from communication
 
 
 
 
Operation hold (hold of 3-wire operation)
 
 
PID integral/differential clear
PID characteristics switching
 
 
Forced run operation
 
 
 
 
Fire speed operation
 
 
Acceleration/deceleration suspend signal
Power failure synchronized signal
 
 
Factory specific coefficient *1
 
 
 
 
Factory specific coefficient *1
*1: Factory specific coefficients are manufacturer setting menus. Do not change the value of these parameters.
*2: Active when  (frequency setting mode selection) =  (UP/DOWN from external logic input) is set.
The frequency setup range is from  to  (maximum frequency). The acceleration/deceleration time
relative to the set frequency is / while the acceleration/deceleration speed is not switched.
☆ Refer to section 11.6 for details about the input terminal function.
Parameter
programmed value
Function
Positive
logic
 
 
 
 
 
 
 
 
 
 













 to 



G-5
Function
Negative
logic
Integrating wattmeter (kWh) display
 
clear
 
Trace back trigger signal
 
Light-load high-speed operation
prohibitive signal
 
Holding of RY-RC terminal output
 
Holding of OUT-NO terminal output
Frequency UP *2
 
Frequency DOWN *2
 
 
Clear frequency UP/DOWN *2
 
Coast stop command
 
Forward/reverse selection
Run/Stop command

Frequency reference command forced

switching
Frequency setting mode terminal block

Command mode terminal block


Parameter editing permission
Fast stop command 1

Fast stop command 2

Traverse permission signal

Low voltage operation


Forward deceleration

Forward stop
Reverse deceleration

Reverse stop

Factory specific coefficient *1

No.2 motor switching
Parameter editing prohibition

Parameter reading prohibition

E6581611
7