Specifications; Models And Their Standard Specifications - Toshiba Q9 Plus Bypass ASD Installation & Operation Manual

Hide thumbs Also See for Q9 Plus Bypass ASD:
Table of Contents

Advertisement

12. Specifications

12.1 Models and their standard specifications

 Standard specifications
Item
Input voltage
Applicable motor (kW)
Type
Form
Capacity (kVA) Note 1)
Rated output/current
(A) Note 2)
Output voltage Note 3)
Overload current rating
Voltage-frequency
Allowable fluctuation
Required Power supply
capacity (kVA) Note 5)
Protection degree (IEC60529)
Cooling method
Color
Built-in filter
Item
Input voltage
Applicable motor (kW)
Type
Form
Capacity (kVA) Note 1)
Rated output current
(A) Note 2)
Rated output voltage Note 3)
Overload current rating
Voltage-current
Allowable fluctuation
Required Power supply
capacity (kVA) Note 5)
Protection degree (IEC60529)
Cooling method
Color
Built-in filter
Note 1. Capacity is calculated at 220V for the 240V models, at 440V for the 500V models.
Note 2. Indicates rated output current setting when the PWM carrier frequency (parameter f300) is 4kHz or less. When
exceeding 4kHz, the rated output current setting is indicated in the parentheses. It needs to be further reduced for
PWM carrier frequencies above 12 kHz.
The rated output current is reduced even further for 500V models with a supply voltage of 480V or more.
The default setting of the PWM carrier frequency is 12kHz.
Note 3. Maximum output voltage is the same as the input voltage.
Note 4. At 180V-264V for the 240V models, at 342V-550V for the 500V models when the inverter is used continuously (load of
100%).
0.4
0.75
1.5
2004PM-W 2007PM-W 2015PM-W 2022PM-W 2037PM-W 2055PM-W 2075PM-W 2110PM-W 2150PM-W
1.3
1.8
3.0
3.3
4.8
8.0
(3.3)
(4.4)
(7.9)
Voltage 170V to 264V Note 4), frequency ±5%
1.4
2.5
4.3
Self-cooling
1-phase 240V
0.2
0.4
0.75
1.5
VFS15S
2002PL
2004PL
2007PL
2015PL
2022PL
-W
-W
-W
-W
0.6
1.3
1.8
3.0
1.5
3.3
4.8
8.0
(1.5)
(3.3)
(4.4)
(7.9)
(10.0)
3-phase 200V to 240V
150%-60 seconds, 200%-0.5 second
1-phase 200V to 240V – 50/60Hz
Voltage 170V to 264V Note 4),
frequency±5%
0.8
1.4
2.3
4.0
IP20
Forced air-
Self-cooling
cooled
RAL7016
EMC filter
Specification
3-phase 240V
2.2
4.0
5.5
VFS15
4.2
6.7
10.5
11.0
17.5
27.5
(10.0)
(16.4)
(25.0)
3-phase 200V to 240V
150%-60 seconds, 200%-0.5 second
3-phase 200V to 240V - 50/60Hz
5.7
9.2
13.8
IP20
Forced air-cooled
RAL7016
Basic filter
Specification
2.2
0.4
0.75
1.5
2.2
4004PL
4007PL
4015PL
4022PL
-W
-W
-W
-W
-W
4.2
1.1
1.8
3.1
4.2
11.0
1.5
2.3
4.1
5.5
(1.5)
(2.1)
(3.7)
(5.0)
3-phase 380V to 500V
150%-60 seconds, 200% -0.5 second
3-phase 380V to 500V - 50/60Hz
Voltage 323V to 550V Note 4), frequency ±5%
5.4
1.6
2.7
4.7
6.4
L-1
E6581611
7.5
11
12.6
20.6
33.0
54.0
(33.0)
(49.0)
17.8
24.3
3-phase 500V
4.0
5.5
7.5
11
VFS15
4037PL
4055PL
4075PL
4110PL
-W
-W
-W
-W
7.2
10.9
13.0
21.1
9.5
14.3
17.0
27.7
(8.6)
(13.0)
(17.0)
(25.0)
10.0
15.2
19.5
26.9
IP20
Forced air-cooled
RAL7016
EMC filter
15
25.1
66.0
(60.0)
31.6
15
4150PL
-W
25.1
33.0
(30.0)
34.9
12