6.39 Permanent magnet motors

f910 : Step-out detection current level
f911 : Step-out detection time
f912 : q-axis inductance
f913 : d-axis inductance
f915 : Factory specific coefficient 9L
• Function
If the permanent magnet motor (PM motor) steps out and if the exciting current increases (it increases
in such a case) and remains above the value set with f910 for the period of time set with f911,
the inverter will judge the motor to be stepping out and trip it. At that time, the trip message
"sout" is displayed.