Appendix 2.7 R220 Cable (+24Vdc Input) - Mitsubishi Electric MELDASMAGIC64 Connection Manual

Hide thumbs Also See for MELDASMAGIC64:
Table of Contents

Advertisement

Cable type name: R220 cable
Application: +24V supply to the base I/O unit, relay card and remote I/O unit
Input of emergency stop signal to the relay card
Assembly drawing
(1)(2)
(3)
R220
R220
Connection diagram
+24V
GND
FG
Manufacturing precautions
(1) The wire material shall be a shielded, 1-pair stranded cable equivalent to AWG18 (0.75mm
If the cable length exceeds 15m, select wire material equivalent to AWG16.
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used
providing they are compatible with the specifications.
(3) Attach the nameplate with protective cover stamped with the cable name in the position
designated in the assembly drawing.
(4) Stamp the name of each signal on the crimp terminal side mark tube and install.
(5) Protect both ends of the wire with an insulating bush.
(6) Use shield processing wire material equivalent to AWG18 (0.75mm
Appendix 2 Cable Manufacturing Drawings
2.7 R220 Cable (+24VDC input)
(4)
1
2
3
Option (compatible connector set)
FCUA-CN220
(Note that this is only compatible with the
base I/O unit, relay card and remote I/O unit
side connectors.)
List of parts used
No. Part name
1
Connector
2
Contact
Wire
3
material
Crimp
4
terminal
Maximum cable length: 30m
+24V
GND
FG
88
Appendix 2.7
Recommended part type Qty
Tyco Electronics AMP
1-178288-3
Tyco Electronics AMP
2-175218-5
DDK
2
JPVV-SB 1P × 0.5 mm
J.S.T. Mfg
V1.25-3
2
).
1
3
(1)
3
2
).

Advertisement

Table of Contents
loading

Table of Contents