Appendix 2.6 R211 Cable (Remote I/O Unit) - Mitsubishi Electric MELDASMAGIC64 Connection Manual

Hide thumbs Also See for MELDASMAGIC64:
Table of Contents

Advertisement

Cable type name: R211 cable
Application: Base I/O unit – Remote I/O unit connection
Remote I/O unit – Remote I/O unit connection
Assembly drawing
(1)(2)
(5)
Connection diagram
TXRX
TXRX*
GND
Manufacturing precautions
(1) The wire material shall be a shielded, 3-core cable equivalent to AWG20 (0.5mm
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used
providing they are compatible with the specifications.
(3) Attach the nameplate with protective cover stamped with the cable name in the position
designated in the assembly drawing.
(4) Protect both ends of the wire with an insulating bush.
(5) Connect the crimp terminal attached to the shield to the frame ground of the base I/O unit or
remote I/O unit.
Note that for noise resistance improvement, in some cases only one end is connected, both
ends are connected or neither end is connected.
Appendix 2 Cable Manufacturing Drawings
2.6 R211 Cable (Remote I/O unit)
(1)(2)
(3)
R211
R211
(4)
1
2
3
FG
Option (compatible connector set)
FCUA-CN211
(Note that there is a single-end connector
and contact, with no crimp terminal.)
List of parts used
No. Part name
Recommended part type Qty
Tyco Electronics AMP
1
Connector
1-178288-3
Tyco Electronics AMP
2
Contact
1-175218-2
Takeuchi Densen
Wire
3
MVVS 3C × 0.5 mm
material
(MIC 3C × 0.5 mm
Crimp
J.S.T. Mfg
4
terminal
V1.25-3
Crimp
J.S.T. Mfg
5
terminal
V1.25-5
Maximum cable length: 50m
TXRX
1
TXRX*
2
3
GND
FG
87
Appendix 2.6
2
6
2
(1)
2
)
1
1
2
).