Mitsubishi Electric MELDASMAGIC64 Connection Manual page 48

Hide thumbs Also See for MELDASMAGIC64:
Table of Contents

Advertisement

Sensor signal
SKIP
8
15
<Cable side connector type>
Connector
Contact
Case
Recommended manufacturer: Hirose Electric
Remote I/O unit
1
RIO1
Remote I/O unit
1
RIO2
+24VDC input
1
DCIN
CAUTION
Do not apply voltages other than those indicated in this manual on the connector. Doing
so may lead to destruction or damage.
Incorrect connections may damage the devices, so connect the cables to the specified
connectors.
5. Base I/O Unit Connection
5.4 Base I/O Unit Connector Pin Assignment
1
9
: CDA-15P
: CD-PC-111
: HDA-CTH
<Cable side connector type>
2
3
Connector : 1-178288-3
Contact
Recommended manufacturer: Tyco Electronics AMP
<Cable side connector type>
2
3
Connector : 1-178288-3
Contact
Recommended manufacturer: Tyco Electronics AMP
<Cable side connector type>
2
3
Connector : 2-178288-3
Contact
Recommended manufacturer: Tyco Electronics AMP
1
GND
2
I
SKIP IN1
3
I
SKIP IN3
4
5
I
SKIP IN5
6
I
SKIP IN7
7
8
GND
(Note) I/O in the table is from the viewpoint of
the base I/O unit.
: 1-175218-5
(Note) I/O in the table is from the viewpoint of
the base I/O unit.
: 1-175218-5
(Note) I/O in the table is from the viewpoint of
the base I/O unit.
: 1-175218-5
(Note) I/O in the table is from the viewpoint of
the base I/O unit.
36
9
GND
10
SKIP IN2
I
11
SKIP IN4
I
12
13
SKIP IN6
I
14
SKIP IN8
I
15
GND
1
I/O
TXRX1
2
I/O
TXRX1*
3
GND
1
I/O
TXRX2
2
I/O
TXRX2*
3
GND
I
1
+24V
2
GND
3
FG