7.8 Connection of FCUA-DX10*/13*/14* Unit and Machine Control Signal
<Signal assignment table>
When using more than two remote
I/O units, the signal assignments will
change. Refer to the "PLC Interface
Machine side
Manual (BNP-B2211)" for details.
control panel, etc.
+24VDC
0V
+24VDC
RA
PL
0V
+24VDC
0V
<Adaptive connection>
DCIN (CN220)
Connector: 2-178288-3
Contact
: 1-175218-5
Manufacturer:
Tyco Electronics AMP
7. Remote I/O Unit Connection (FCUA-DX1**)
<CAUTION>
Base I/O unit
R-TM
Remote I/O unit
RIO1/RIO2 (CN211)
Connector: 1-178288-3
Contact
: 1-175218-2
Manufacturer:
Tyco Electronics AMP
FCUA-DX10*/13*/14*
B
X00
X01
X02
X03
X04
X05
X06
DI-L
X07
X08
X09
X0A
X0B
X0C
X0D
X0E
X0F
COM
+24V
+24V
B
B
Y00
Y01
Y02
Y03
Y04
Y05
Y06
Y07
DO-L
Y08
DO-L
Y09
Y0A
Y0B
Y0C
Y0D
Y0E
Y0F
+24V
+24V
B
RI01
1
2
T
R
T
R
*
LG
X
X
X
X
X
AMP
D-3
DI-L/DO-L(CN300)
Crimp type connector:
7940-6500SC
Manufacturer:
Sumitomo 3M
60
DI-L
A
X10
20
19
X11
18
X12
X13
17
X14
16
15
X15
14
X16
X17
13
X18
12
X19
11
10
X1A
X1B
9
X1C
8
X1D
7
6
X1E
5
X1F
4
COM
3
2
0V
1
0V
A
DO-L
A
Y10
20
Y11
19
Y12
18
Y13
17
Y14
16
Y15
15
Y16
14
Y17
13
Y18
12
Y19
11
Y1A
10
Y1B
9
Y1C
8
Y1D
7
Y1E
6
Y1F
5
4
3
0V
2
0V
1
A
RI02
DCIN
3
1
2
3
1
2
T
R
T
R
*
LG
+24V
0V
X
X
X
X
X
Y
AMP
AMP
D-3
D-3
Terminator (R-TM)
X
D-3
Manufacturer:
Tyco Electronics AMP
3
FG
AMP