7.13 Connection of FCUA-DX14* Unit and Analog Input/Output Signal

7.13 Connection of FCUA-DX14* Unit and Analog Input/Output Signal
For the analog input/output signal, the R031 cable is connected to "AIO". Up to four input points and
one output point of the analog input/output signal can be connected. When manufacturing the R031,
use the connector set CS000 (optional, with two ends). (Refer to the Appendix 2.3. R031 cable.)
R031 cable
Input/output circuit
Connector pin No.
AI0
AI1
Input
AI2
AI3
Output
GND
GND
GND
GND
CAUTION
Incorrect connections could damage the device, so always connect the cable to the
designated connector.
Do not connect or disconnect the connection cables between each unit while the power
is ON.
7. Remote I/O Unit Connection
FCUA-DX14*
150
2
150
12
150
3
150
13
220
AO
7
1
11
5
15
AIO
20
11
Pin No.
ADC
R
R
DAC
67
FCUA-DX14