7. Remote I/O Unit Connection (FCUA-DX1**)

7.1 Outline of Remote I/O Unit

The eight types of signals that can be input/output from the remote I/O unit (FCUA-DX1**) are shown
below according to the type and No. of contacts. Use with serial link connections (MC link B) to the NC
Card.
When the remote I/O unit is connected with serial links, multiple units can be used as long as the total
No. of occupied stations (channels) is within 8 channels. (Refer to "7.14 Setting of Channel No. When
Using Multiple Remote I/O Units" for station No. setting details.)
Unit name
Digital input signal (DI)
FCUA-DX100
Digital output signal (DO) : 32 points (non-insulation)
Digital input signal (DI)
FCUA-DX101
Digital output signal (DO) : 32 points (non-insulation)
Digital input signal (DI)
FCUA-DX110
Digital output signal (DO) : 48 points (non-insulation)
Digital input signal (DI)
FCUA-DX111
Digital output signal (DO) : 48 points (non-insulation)
Digital input signal (DI)
FCUA-DX120
Digital output signal (DO) : 48 points (non-insulation)
Analog output (AO)
Digital input signal (DI)
FCUA-DX121
Digital output signal (DO) : 48 points (non-insulation)
Analog output (AO)
Digital input signal (DI)
FCUA-DX130
Digital output signal (DO) : 32 points (non-insulation)
Handle input
Digital input signal (DI)
FCUA-DX131
Digital output signal (DO) : 32 points (non-insulation)
Handle input
Digital input signal (DI)
Digital output signal (DO) : 32 points (non-insulation)
FCUA-DX140
Analog input (AI)
Analog output (AO)
Digital input signal (DI)
Digital output signal (DO) : 32 points (non-insulation)
FCUA-DX141
Analog input (AI)
Analog output (AO)
7. Remote I/O Unit Connection (FCUA-DX1**)
7.1 Outline of Remote I/O Unit
Machine control signals that can be input/output
: 32 points (photo coupler insulation) sink/source type
: 32 points (photo coupler insulation) sink/source type
: 64 points (photo coupler insulation) sink/source type
: 64 points (photo coupler insulation) sink/source type
: 64 points (photo coupler insulation) sink/source type
: 1 point
: 64 points (photo coupler insulation) sink/source type
: 1 point
: 32 points (photo coupler insulation) sink/source type
: 2 channels
: 32 points (photo coupler insulation) sink/source type
: 2 channels
: 32 points (photo coupler insulation) sink/source type
: 4 points
: 1 point
: 32 points (photo coupler insulation) sink/source type
: 4 points
: 1 point
sink type
source type
sink type
source type
sink type
source type
sink type
source type
sink type
source type
51
No. of occupied
serial link channels
1
1
2
2
2
2
2
2
2
2