Cables which require shield clamp with a connector cases are shown following table.
<Shield clamp method>
Fold the wire material shield over the sheath, and wrap copper foil tape over it. Connect the wrapped
copper foil tape to the connector case GND plate.
Unit name
NC Card
(HR621/HR623/
FCU6-HR655)
Base I/O unit
(FCU6-DX2 ∗∗ , 3 ∗∗ ,
4 ∗∗ )
Relay card
(HR682)
(Note) RS-232C uses only the DC code (X ON/OFF) method handshake.
(3) Connecting Spark Killers
Connect a spark killer on the coil or relay contact in parallel for noise countermeasures.
Use spark killers which are 0.033~0.1µF, 10~120Ω.
3. Installation
3.3 Installation
Connector
Connection destination
name
CF10
Base I/O unit
CF61
Relay card
CF10
NC Card
SV1
Servo drive unit
SV2
Servo drive unit
ENC1
Spindle encoder
SKIP
Skip
PI01
Remote I/O unit
PI02
Remote I/O unit
CF61
NC Card
ENC#2
Spindle encoder
HANDLE
Manual pulse generator
RS232C
RS-232C (I/O device)
(Note)
Contact
SK
E
Treatment of cable ends
Connection origin
(NC Card) Not required
(NC Card) Not required
(Base I/O unit) Not required
(Base I/O unit) Required
(Base I/O unit) Required
(Base I/O unit) Required
(Base I/O unit) Required
(Base I/O unit) Required
(Base I/O unit) Required
(Relay card) Not required
(Relay card) Required
(Relay card) Required
(Relay card) Required
14
Connection
destination
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Coil